Socomec netys-pr-netys-rt-itys
Netys-PR-Netys-RT-Itys
Socomec netys-pr-netys-rt-itys (ups) ha una mappa Modbus di 50 registri. Function code usati: 3 (holding register). Tipi di dato: uint16. Esempi: Broadcast,-load-phase-1-(M00) all'indirizzo 96 (FC 3, uint16, %); Broadcast,-total-load-(M03) all'indirizzo 99 (FC 3, uint16, %); Broadcast,-battery-capacity-(M04) all'indirizzo 100 (FC 3, uint16, %); Broadcast,-auxiliary-mains-star-voltage-v1-(M06) all'indirizzo 102 (FC 3, uint16, %).
UPSDa documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- %
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- %
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- %
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- %
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- V
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- A
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- Hz
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- Hz
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- V
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- DC
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 96 | Broadcast,-load-phase-1-(M00) Broadcast,-load-phase-1-(M00) | broadcast_load_phase_1_m00 | 3 | uint16 | 1 | 1 | % | R | — | |
| 99 | Broadcast,-total-load-(M03) Broadcast,-total-load-(M03) | broadcast_total_load_m03 | 3 | uint16 | 1 | 1 | % | R | — | |
| 100 | Broadcast,-battery-capacity-(M04) Broadcast,-battery-capacity-(M04) | broadcast_battery_capacity_m04 | 3 | uint16 | 1 | 1 | % | R | — | |
| 102 | Broadcast,-auxiliary-mains-star-voltage-v1-(M06) Broadcast,-auxiliary-mains-star-voltage-v1-(M06) | broadcast_auxiliary_mains_star_voltage_v1_m06 | 3 | uint16 | 1 | 1 | % | R | — | |
| 105 | Broadcast,-output-star-voltage-v1-(M09) Broadcast,-output-star-voltage-v1-(M09) | broadcast_output_star_voltage_v1_m09 | 3 | uint16 | 1 | 1 | V | R | — | |
| 111 | Broadcast,-output-current-phase-l1-(M15) Broadcast,-output-current-phase-l1-(M15) | broadcast_output_current_phase_l1_m15 | 3 | uint16 | 1 | 1 | A | R | — | |
| 114 | Broadcast,-auxiliary-frequency-(M18) Broadcast,-auxiliary-frequency-(M18) | broadcast_auxiliary_frequency_m18 | 3 | uint16 | 1 | 1 | Hz | R | — | |
| 115 | Broadcast,-output-frequency-(M19) Broadcast,-output-frequency-(M19) | broadcast_output_frequency_m19 | 3 | uint16 | 1 | 1 | Hz | R | — | |
| 116 | Broadcast,-positive-battery-voltage-(M20) Broadcast,-positive-battery-voltage-(M20) | broadcast_positive_battery_voltage_m20 | 3 | uint16 | 1 | 1 | V | R | — | |
| 118 | Broadcast,-internal-UPS-temperature-(M22) Broadcast,-internal-UPS-temperature-(M22) | broadcast_internal_ups_temperature_m22 | 3 | uint16 | 1 | 1 | DC | R | — |
Stai vedendo 10 registri su 50.