Siemens VersiCharge AC series
VersiCharge AC series
Siemens VersiCharge AC series (colonnine di ricarica (evse)) ha una mappa Modbus di 56 registri, riferita al firmware 2.135+. Function code usati: 3 (holding register). Tipi di dato: int16, string, uint16, uint32. Esempi: Manufacturer Name all'indirizzo 0 (FC 3, string); Serial Number all'indirizzo 7 (FC 3, string); MLFB Number all'indirizzo 12 (FC 3, string); Platform Type all'indirizzo 22 (FC 3, uint16).
Colonnine di ricarica (EVSE)Da documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- string
- Unità
- —
- Scala
- 1
- Len
- 5
- Accesso
- R
- FC
- 3
- Tipo
- string
- Unità
- —
- Scala
- 1
- Len
- 5
- Accesso
- R
- FC
- 3
- Tipo
- string
- Unità
- —
- Scala
- 1
- Len
- 10
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- A
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- A
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | Manufacturer Name The user can get the Manufacturer Name using this register. | manufacturer_name | 3 | string | 5 | 1 | — | R | big | |
| 7 | Serial Number The user can get the Product Serial Number using this register. | serial_number | 3 | string | 5 | 1 | — | R | big | |
| 12 | MLFB Number The user can get the Product Catalog Number using this register. | mlfb_number | 3 | string | 10 | 1 | — | R | big | |
| 22 | Platform Type The user can get the charger platform type: 1 -Residential, 2 - Commercial 3 - ERK | platform_type | 3 | uint16 | 1 | 1 | — | R | big | |
| 24 | Number of Outlets The user can get the number of charging outlets: 1 - 1 outlet 2 - 2 outlets | number_of_outlets | 3 | uint16 | 1 | 1 | — | R | big | |
| 25 | Type of Outlet The user can get the type of outlet: 0 - Left: socket type 2 | type_of_outlet | 3 | uint16 | 1 | 1 | — | R | big | |
| 26 | Delay Button Status Get Delay state of the charger: 0 - No delay 1 - 2 Hours delay 2 - 4 Hours delay 3 - 6 Hours delay 4 - 8 Hours delay | delay_button_status | 3 | uint16 | 1 | 1 | — | R | big | |
| 27 | Utilized Connectivity Stream This register returns the stream through which the charger is commissioned: 0 - Not Commissioned 1 - Wi-Fi 2 – Cellular 3 - Ethernet Note: - Modbus application will not start if charger is not commissioned. - Modbus application will only start in commissioned charger if "Modbus" configuration is "Tr… | utilized_connectivity_stream | 3 | uint16 | 1 | 1 | — | R | big | |
| 28 | Rated Current Rated (Maximum) Amps value which is configured from system configuration (6 to 80 Amps) | rated_current | 3 | uint16 | 1 | 1 | A | R | big | |
| 29 | Installation Current (DIP switch) Derated setting Value in Ampere (Based on Amp switch setting) (6 to 80 Amps) Below table for ampere rating as per switch position Switch ------- UL -------- IEC position ------ (amps) --- (amps) 0 --------- 12 --------- 10 1 --------- 16 --------- 13 2 --------- 24 --------- 16 3 --------- 32 ------… | installation_current_dip_switch | 3 | uint16 | 1 | 1 | A | R | big |