Schneider Electric EM4200
EM4200
Schneider Electric EM4200 (contatori e analizzatori) ha una mappa Modbus di 369 registri. Function code usati: 3 (holding register). Tipi di dato: float32, int16, int32, string, uint16, uint32. Esempi: System Type: See Manual. all'indirizzo 36 (FC 3, uint16, integer); Sub–Interval Length: Sets the length of a sub–interval. Value is the number of seconds times 5 (for example, 15 minut… all'indirizzo 37 (FC 3, uint16, integer); Number of sub-intervals per demand interval. Sets the number of sub-intervals that make a single demand interval. Leg… all'indirizzo 38 (FC 3, uint16, integer); Command (39) all'indirizzo 39 (FC 3, uint16, bit map).
Contatori e analizzatoriMappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- integer
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- integer
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- integer
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- bit map
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- float32
- Unità
- kWh
- Scala
- 1
- Len
- 2
- Accesso
- R/W
- FC
- 3
- Tipo
- float32
- Unità
- kWh
- Scala
- 1
- Len
- 2
- Accesso
- R/W
- FC
- 3
- Tipo
- float32
- Unità
- kW
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- float32
- Unità
- kvar
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- float32
- Unità
- kVA
- Scala
- 1
- Len
- 2
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 36 | System Type: See Manual. 20 = Single Phase, 2-Wire: L1 + N 20 = Single Phase, 2-Wire: L1 + L2 21 = Single Split Phase, 3-Wire: L1 + L2 + N 30 = 3 Phase Delta, ∆, L1 + L2 + L3, no N 40 = 3 Phase Wye, Y, L1 + L2 + L3 + N. Range: 20 21 30 40 | system_type_see_manual | 3 | uint16 | 1 | 1 | integer | R/W | big | |
| 37 | Sub–Interval Length: Sets the length of a sub–interval. Value is the number of seconds times 5 (for example, 15 minut… Sub–Interval Length: Sets the length of a sub–interval. Value is the number of seconds times 5 (for example, 15 minutes is 4500). For sync–to–comms, set this to zero. | sub_interval_length_sets_the_length_of_a_sub_interval_value_is_the_number_of_seconds_times_5_for_example_15_minut | 3 | uint16 | 1 | 1 | integer | R/W | big | |
| 38 | Number of sub-intervals per demand interval. Sets the number of sub-intervals that make a single demand interval. Leg… Number of sub-intervals per demand interval. Sets the number of sub-intervals that make a single demand interval. Legal values are 1 to 6. For block demand, set this to 1. | number_of_sub_intervals_per_demand_interval_sets_the_number_of_sub_intervals_that_make_a_single_demand_interval_leg | 3 | uint16 | 1 | 1 | integer | R/W | big | |
| 39 | Command (39) bit 0 (mask 1) = Begin new demand sub-interval bit 1 (mask 2) = Clear kWH accumulator (only command supported on Basic model) bit 2 (mask 3) = Reset peak demand. Range: 0x00 - 0x07 | command_39 | 3 | uint16 | 1 | 1 | bit map | R/W | big | |
| 40 | Reserved, Returns 0x8000 (QNAN) (40) | reserved_returns_0x8000_qnan_40 | 3 | uint16 | 1 | 1 | — | R | big | |
| 257 | Real Energy Consumption Clear by writing a 0 to either integer kWh register #1 or 2 | real_energy_consumption | 3 | float32 | 2 | 1 | kWh | R/W | big | |
| 259 | Real Energy Consumption (redundant) | real_energy_consumption_redundant | 3 | float32 | 2 | 1 | kWh | R/W | big | |
| 261 | Total Instantaneous Real Power | total_instantaneous_real_power | 3 | float32 | 2 | 1 | kW | R | big | |
| 263 | Total Instantaneous Reactive Power | total_instantaneous_reactive_power | 3 | float32 | 2 | 1 | kvar | R | big | |
| 265 | Total Instantaneous Apparent Power | total_instantaneous_apparent_power | 3 | float32 | 2 | 1 | kVA | R | big |
Stai vedendo 10 registri su 369.