Intesis INMBSPAN001R000
INMBSPAN001R000
Intesis INMBSPAN001R000 (datalogger e gateway) ha una mappa Modbus di 54 registri. Function code usati: 3 (holding register). Tipi di dato: int16, uint16. Esempi: AC unit On/Off all'indirizzo 0 (FC 3, uint16); AC unit Mode all'indirizzo 1 (FC 3, uint16); AC unit Fan Speed all'indirizzo 2 (FC 3, uint16); AC unit Vane Position all'indirizzo 3 (FC 3, uint16).
Datalogger e gatewayDa documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- int16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- int16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | AC unit On/Off | ac_unit_on_off | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 1 | AC unit Mode | ac_unit_mode | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 2 | AC unit Fan Speed | ac_unit_fan_speed | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 3 | AC unit Vane Position | ac_unit_vane_position | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 4 | AC unit Temperature Setpoint -32768 (Initialization value) 16..32ºC (ºC/x10ºC) 61..90ºF Degrees or tenths of a degree, °C or °F, as set with the DIP switches; -32768 means not initialised. | ac_unit_temperature_setpoint | 3 | int16 | 1 | 1 | — | R/W | big | |
| 5 | AC unit Temperature reference -32768: Initialization value. Value invalid, which comes from the IU’s sensor. If the value that is shown in register 22 (23 PLC) is valid, the address is going to take this value. Ranges are specific from Manufacturer (ºC/x10ºC/ºF) Degrees or tenths of a degree, °C or °F, as set with the DIP switches; -32768 means not initialised. | ac_unit_temperature_reference | 3 | int16 | 1 | 1 | — | R/W | big | |
| 6 | Window Contact | window_contact | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 7 | Gateway Disablement | gateway_disablement | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 8 | AC Remote Control Disablement | ac_remote_control_disablement | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 9 | AC unit Operation Time 0..65535 (hours). Counts the time the AC unit is in “On” state. | ac_unit_operation_time | 3 | uint16 | 1 | 1 | — | R/W | big |
Stai vedendo 10 registri su 54.