Huawei solar-inverter (inverter) ha una mappa Modbus di 50 registri. Function code usati: 3 (holding register). Tipi di dato: int16, int32, uint16, uint32. Esempi: Model-id all'indirizzo 69 (FC 3, uint16); Number-of-mpp-trackers all'indirizzo 71 (FC 3, uint16); Rated-power all'indirizzo 72 (FC 3, uint32, kW); Maximum-active-power-(-max) all'indirizzo 74 (FC 3, uint32, kW).
InverterDa documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint32
- Unità
- kW
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- uint32
- Unità
- kW
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- uint32
- Unità
- kVA
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- int32
- Unità
- kVar
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- int32
- Unità
- kVar
- Scala
- 1
- Len
- 2
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 69 | Model-id Model-id | model_id | 3 | uint16 | 1 | 1 | — | R | — | |
| 71 | Number-of-mpp-trackers Number-of-mpp-trackers | number_of_mpp_trackers | 3 | uint16 | 1 | 1 | — | R | — | |
| 72 | Rated-power Rated-power | rated_power | 3 | uint32 | 2 | 1 | kW | R | — | |
| 74 | Maximum-active-power-(-max) Maximum-active-power-(-max) | maximum_active_power_max | 3 | uint32 | 2 | 1 | kW | R | — | |
| 76 | Maximum-apparent-power-(smax) Maximum-apparent-power-(smax) | maximum_apparent_power_smax | 3 | uint32 | 2 | 1 | kVA | R | — | |
| 78 | Maximum-reactive-power-(qmax,-fed-to-the-power-grid) Maximum-reactive-power-(qmax,-fed-to-the-power-grid) | maximum_reactive_power_qmax_fed_to_the_power_grid | 3 | int32 | 2 | 1 | kVar | R | — | |
| 80 | Maximum-reactive-power-absorbed-from-the-power-grid) Maximum-reactive-power-absorbed-from-the-power-grid) | maximum_reactive_power_absorbed_from_the_power_grid | 3 | int32 | 2 | 1 | kVar | R | — | |
| 1999 | State-1 State-1 | state_1 | 3 | uint16 | 1 | 1 | — | R | — | |
| 2008 | Alarm-2 Alarm-2 | alarm_2 | 3 | uint16 | 1 | 1 | — | R | — | |
| 2009 | Alarm-3 Alarm-3 | alarm_3 | 3 | uint16 | 1 | 1 | — | R | — |