Grundfos Hydro MPC & Multi-E (CIM 200/500)
Hydro MPC & Multi-E (CIM 200/500)
Grundfos Hydro MPC & Multi-E (CIM 200/500) (plc, controllori e i/o) ha una mappa Modbus di 127 registri. Function code usati: 3 (holding register). Tipi di dato: bitfield, uint16, uint32. Esempi: SlaveMinimumReplyDelay all'indirizzo 0 (FC 3, uint16, ms); SoftwareDefinedModbusAddress all'indirizzo 2 (FC 3, uint16); SoftwareDefinedBitRate all'indirizzo 3 (FC 3, uint16); AutoAckControlBits all'indirizzo 4 (FC 3, uint16).
PLC, controllori e I/ODa documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- ms
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- s
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | SlaveMinimumReplyDelay Extra reply delay added by the CIM 200 (0-10000 ms). | slaveminimumreplydelay | 3 | uint16 | 1 | 1 | ms | R/W | big | |
| 2 | SoftwareDefinedModbusAddress Slave address used only in software-defined mode (CIM 200). | softwaredefinedmodbusaddress | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 3 | SoftwareDefinedBitRate Baud rate used only in software-defined mode (CIM 200). | softwaredefinedbitrate | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 4 | AutoAckControlBits 1 = CIM lowers triggered control bits automatically. | autoackcontrolbits | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 8 | SoftwareDefinedParity Parity used only in software-defined mode (CIM 200). | softwaredefinedparity | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 9 | SoftwareDefinedStopBit Stop bits used only in software-defined mode (CIM 200). | softwaredefinedstopbit | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 11 | Watchdog Comm-loss timeout; 0 disables. On timeout the booster reverts to Local mode. | watchdog | 3 | uint16 | 1 | 1 | s | R/W | big | |
| 23 | ActualModbusAddress Slave address currently in use. | actualmodbusaddress | 3 | uint16 | 1 | 1 | — | R | big | |
| 29 | UnitFamily Product family code (e.g. 21 = Hydro/Control MPC). | unitfamily | 3 | uint16 | 1 | 1 | — | R | big | |
| 30 | UnitType Product type within the family (see manual). | unittype | 3 | uint16 | 1 | 1 | — | R | big |