fronius inverter-110-111
inverter-110-111
Importata da documento
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 40005 | Manufacturer Manufacturer | manufacturer | 3 | string | — | 1 | — | R | — | |
| 40021 | Device-model Device-model | device_model | 3 | string | — | 1 | — | R | — | |
| 40037 | Options Options | options | 3 | string | — | 1 | — | R | — | |
| 40045 | Sw-version-of-inverter Sw-version-of-inverter | sw_version_of_inverter | 3 | string | — | 1 | — | R | — | |
| 40053 | Serialnumber-of-the-inverter Serialnumber-of-the-inverter | serialnumber_of_the_inverter | 3 | string | — | 1 | — | R | — | |
| 40069 | Modbus-device-address Modbus-device-address | modbus_device_address | 3 | uint16 | 1 | 1 | — | R | — | |
| 40072 | Ac-total-current-value Ac-total-current-value | ac_total_current_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40074 | Ac-phase-A-current-value Ac-phase-A-current-value | ac_phase_a_current_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40076 | Ac-phase-B-current-value Ac-phase-B-current-value | ac_phase_b_current_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40078 | Ac-phase-C-current-value Ac-phase-C-current-value | ac_phase_c_current_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40080 | Ac-voltage-phase-ab-value Ac-voltage-phase-ab-value | ac_voltage_phase_ab_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40082 | Ac-voltage-phase-bc-value Ac-voltage-phase-bc-value | ac_voltage_phase_bc_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40084 | Ac-voltage-phase-ca-value Ac-voltage-phase-ca-value | ac_voltage_phase_ca_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40086 | Ac-voltage-phase-A-to-neutral-value Ac-voltage-phase-A-to-neutral-value | ac_voltage_phase_a_to_neutral_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40088 | Ac-voltage-phase-B-to-neutral-value Ac-voltage-phase-B-to-neutral-value | ac_voltage_phase_b_to_neutral_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40090 | Ac-voltage-phase-C-to-neutral-value Ac-voltage-phase-C-to-neutral-value | ac_voltage_phase_c_to_neutral_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40092 | Ac-power-value Ac-power-value | ac_power_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40094 | Ac-frequency-value Ac-frequency-value | ac_frequency_value | 3 | float32 | 2 | 1 | Hz | R | — | |
| 40096 | Apparent-power Apparent-power | apparent_power | 3 | float32 | 2 | 1 | VA | R | — | |
| 40098 | Reactive-power Reactive-power | reactive_power | 3 | float32 | 2 | 1 | VAr | R | — | |
| 40100 | Power-factor Power-factor | power_factor | 3 | float32 | 2 | 1 | — | R | — | |
| 40102 | Ac-lifetime-energy-production Ac-lifetime-energy-production | ac_lifetime_energy_production | 3 | float32 | 2 | 1 | Wh | R | — | |
| 40108 | Dc-power-value Dc-power-value | dc_power_value | 3 | float32 | 2 | 1 | — | R | — | |
| 40120 | Event-flags-(bits-0-31) Event-flags-(bits-0-31) | event_flags_bits_0_31 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40122 | Event-flags-(bits-32-63) Event-flags-(bits-32-63) | event_flags_bits_32_63 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40124 | Vendor-defined-event-flags-(bits-0-31) Vendor-defined-event-flags-(bits-0-31) | vendor_defined_event_flags_bits_0_31 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40126 | Vendor-defined-event-flags-(bits-32-63) Vendor-defined-event-flags-(bits-32-63) | vendor_defined_event_flags_bits_32_63 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40128 | Vendor-defined-event-flags-(bits-64-95) Vendor-defined-event-flags-(bits-64-95) | vendor_defined_event_flags_bits_64_95 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40130 | Vendor-defined-event-flags-(bits-96-127) Vendor-defined-event-flags-(bits-96-127) | vendor_defined_event_flags_bits_96_127 | 3 | uint32 | 2 | 1 | — | R | — | |
| 40133 | Length-of-nameplate-model Length-of-nameplate-model | length_of_nameplate_model | 3 | uint16 | 1 | 1 | — | R | — | |
| 40135 | Continuous-power-output-capability-of-the-inverter Continuous-power-output-capability-of-the-inverter | continuous_power_output_capability_of_the_inverter | 3 | uint16 | 1 | 1 | — | R | — | |
| 40137 | Continuous-volt-ampere-capability-of-the-inverter Continuous-volt-ampere-capability-of-the-inverter | continuous_volt_ampere_capability_of_the_inverter | 3 | uint16 | 1 | 1 | VA | R | — | |
| 40139 | Continuous-var-capability-of-the-inverter-in-quadrant-1 Continuous-var-capability-of-the-inverter-in-quadrant-1 | continuous_var_capability_of_the_inverter_in_quadrant_1 | 3 | int16 | 1 | 1 | var | R | — | |
| 40142 | Continuous-var-capability-of-the-inverter-in-quadrant-4 Continuous-var-capability-of-the-inverter-in-quadrant-4 | continuous_var_capability_of_the_inverter_in_quadrant_4 | 3 | int16 | 1 | 1 | var | R | — | |
| 40144 | Maximum-rms-ac-current-level-capability-of-the-inverter Maximum-rms-ac-current-level-capability-of-the-inverter | maximum_rms_ac_current_level_capability_of_the_inverter | 3 | uint16 | 1 | 1 | — | R | — | |
| 40146 | Minimum-power-factor-capability-of-the-inverter-in-quadrant-1 Minimum-power-factor-capability-of-the-inverter-in-quadrant-1 | minimum_power_factor_capability_of_the_inverter_in_quadrant_1 | 3 | int16 | 1 | 1 | — | R | — | |
| 40149 | Minimum-power-factor-capability-of-the-inverter-in-quadrant-4 Minimum-power-factor-capability-of-the-inverter-in-quadrant-4 | minimum_power_factor_capability_of_the_inverter_in_quadrant_4 | 3 | int16 | 1 | 1 | — | R | — | |
| 40151 | Nominal-energy-rating-of-storage-device Nominal-energy-rating-of-storage-device | nominal_energy_rating_of_storage_device | 3 | uint16 | 1 | 1 | Wh | R | — | |
| 40155 | Maximum-rate-of-energy-transfer-into-the-storage-device Maximum-rate-of-energy-transfer-into-the-storage-device | maximum_rate_of_energy_transfer_into_the_storage_device | 3 | uint16 | 1 | 1 | — | R | — | |
| 40157 | Maximum-rate-of-energy-transfer-out-of-the-storage-device Maximum-rate-of-energy-transfer-out-of-the-storage-device | maximum_rate_of_energy_transfer_out_of_the_storage_device | 3 | uint16 | 1 | 1 | — | R | — | |
| 40161 | Length-of-basic-settings-model Length-of-basic-settings-model | length_of_basic_settings_model | 3 | uint16 | 1 | 1 | — | R | — | |
| 40162 | Setting-for-maximum-power-output.-Default-to-i_wrtg Setting-for-maximum-power-output.-Default-to-i_wrtg | setting_for_maximum_power_output_default_to_i_wrtg | 3 | uint16 | 1 | 1 | — | R | — | |
| 40163 | Voltage-at-the-pcc Voltage-at-the-pcc | voltage_at_the_pcc | 3 | uint16 | 1 | 1 | — | R | — | |
| 40164 | Offset-from-pcc-to-inverter Offset-from-pcc-to-inverter | offset_from_pcc_to_inverter | 3 | int16 | 1 | 1 | — | R | — | |
| 40167 | Setpoint-for-maximum-apparent-power.-Default-to-i_vartg Setpoint-for-maximum-apparent-power.-Default-to-i_vartg | setpoint_for_maximum_apparent_power_default_to_i_vartg | 3 | uint16 | 1 | 1 | VA | R | — | |
| 40168 | Setting-for-maximum-reactive-power-in-quadrant-1.-Default-to-varrtgq1 Setting-for-maximum-reactive-power-in-quadrant-1.-Default-to-varrtgq1 | setting_for_maximum_reactive_power_in_quadrant_1_default_to_varrtgq1 | 3 | int16 | 1 | 1 | var | R | — | |
| 40171 | Setting-for-maximum-reactive-power-in-quadrant-4-default-to-varrtgq4 Setting-for-maximum-reactive-power-in-quadrant-4-default-to-varrtgq4 | setting_for_maximum_reactive_power_in_quadrant_4_default_to_varrtgq4 | 3 | int16 | 1 | 1 | var | R | — | |
| 40173 | Setpoint-for-minimum-power-factor-value-in-quadrant-1.-Default-to-pfrtgq1 Setpoint-for-minimum-power-factor-value-in-quadrant-1.-Default-to-pfrtgq1 | setpoint_for_minimum_power_factor_value_in_quadrant_1_default_to_pfrtgq1 | 3 | int16 | 1 | 1 | — | R | — | |
| 40176 | Setpoint-for-minimum-power-factor-value-in-quadrant-4.-Default-to-pfrtgq4 Setpoint-for-minimum-power-factor-value-in-quadrant-4.-Default-to-pfrtgq4 | setpoint_for_minimum_power_factor_value_in_quadrant_4_default_to_pfrtgq4 | 3 | int16 | 1 | 1 | — | R | — | |
| 40193 | Length-of-measurements_status-model Length-of-measurements_status-model | length_of_measurements_status_model | 3 | uint16 | 1 | 1 | — | R | — |
Leggi questi registri via API
curl https://busbabel.vercel.app/api/devices/fronius/inverter-110-111/registers?version=v1