Daikin Applied Trailblazer AGZ-F Chiller
Trailblazer AGZ-F Chiller
Daikin Applied Trailblazer AGZ-F Chiller (hvac) ha una mappa Modbus di 63 registri, riferita al firmware Chiller application 1.2.0, HMI 1.12.0 (document baseline). Function code usati: 3 (holding register). Tipi di dato: int16, uint16, uint32. Esempi: Chiller Local/Network all'indirizzo 0 (FC 3, uint16); Chiller Enable Output all'indirizzo 1 (FC 3, uint16); Run Enabled all'indirizzo 2 (FC 3, uint16); Chiller Capacity Limited all'indirizzo 3 (FC 3, uint16).
HVACDa documento
Mappa registri Modbus
10 registri
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R/W
- FC
- 3
- Tipo
- uint16
- Unità
- —
- Scala
- 1
- Len
- 1
- Accesso
- R
| Len | Scala | Endian | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| 0 | Chiller Local/Network Network commands are ignored while Local. | chiller_local_network | 3 | uint16 | 1 | 1 | — | R | big | |
| 1 | Chiller Enable Output | chiller_enable_output | 3 | uint16 | 1 | 1 | — | R | big | |
| 2 | Run Enabled | run_enabled | 3 | uint16 | 1 | 1 | — | R | big | |
| 3 | Chiller Capacity Limited | chiller_capacity_limited | 3 | uint16 | 1 | 1 | — | R | big | |
| 4 | Alarm Digital Output Poll this for any active alarm. | alarm_digital_output | 3 | uint16 | 1 | 1 | — | R | big | |
| 5 | Evaporator Flow Switch Status | evaporator_flow_switch_status | 3 | uint16 | 1 | 1 | — | R | big | |
| 7 | Chiller On/Off | chiller_on_off | 3 | uint16 | 1 | 1 | — | R | big | |
| 8 | Chiller Enable Setpoint Network enable; used only when Control Source = BAS. | chiller_enable_setpoint | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 9 | Clear Alarm - Network Write 1 to clear; returns to Normal. | clear_alarm_network | 3 | uint16 | 1 | 1 | — | R/W | big | |
| 10 | Chiller Mode Output | chiller_mode_output | 3 | uint16 | 1 | 1 | — | R | big |
Stai vedendo 10 registri su 63.